Forech

Cintas transportadoras

Fire Resistance Belt

Fuego

Características del producto

  • Compliance: Meets leading international safety standards including EN 14937, EN 12882, ISO 340, FRAS, and MSHA
  • Static Safety: Enhanced static conductivity safely dissipates static electricity, reducing spark risks
  • Durability: Durable design ensures long service life without

Technical Information

Fire Resistant Test Compliance to StandardMinimum Tensile StrengthMinimum Elongation at Break (%)Maximum Abrasion Loss (mm3)Application Characteristics
FR MSHA 2G15350190Moderate resistance to flame for over ground application
FR CAN - C17400175Good resistance to flame for over ground applications
FR DIN K17400175Good resistance to flame for over ground applications
FR IS 189117400175Good resistance to flame for over ground applications
FR - AS F17400175Very good resistance to flame suitable for high risk over ground/low risk underground application
FR - DIN S17400175Very good resistance to flame suitable for high risk over ground/low risk underground application
FR - SANS 971:200317400175Very good resistance to flame suitable for high risk over ground/low risk underground application
FR MSHA BELT (PART 14)15400200Excellent resistance to flame propagation suitable for underground mining application
FR - SANS 971:201315400170Excellent resistance to flame propagation suitable for underground mining application
FR AS 4606:S20400120Excellent resistance to flame propagation suitable for underground mining application

Summary of Safety Classes

CLASSAPPLICATIONSURFACE RESISTANCE EN ISO 284FlameGlowMax. drum temperature °CAggregate of each set of six test piecesMaximum for any one test pieceFIRE PROPAGATION METHOD
AGeneral use, only hazard being limited access and means of escape≤ 300 MΩNoPermittedNo limit< 45/45b15EN 12881-1:2014, Method A. If incomplete ignition achieved, use Method B or C
B1As class A plus potentially flammable atmosphere. No secondary safety devices≤ 300 MΩNoNo450< 45/45b15EN 12881-1:2014, Method A. If incomplete ignition achieved, use Method B or C
B2As class A plus potentially flammable atmosphere. With secondary safety devices≤ 300 MΩNoPermittedNo limit< 45/45b15EN 12881-1:2014, Method A. If incomplete ignition achieved, use Method B or C
C1As class B1 plus combustible dust or material conveyed. No secondary safety devices≤ 300 MΩNoNo325≤ 18/30b10/15bEN 12881-1:2014, Method B or C
C2As class B1 plus combustible dust or material conveyed and additional fuel sources (fire load). With secondary safety devices≤ 300 MΩNoPermittedNo limit< 45/45b15EN 12881-2, or EN 12881-1:2014, Method D for belts according to Table 1